0000046: Invalid padding for 'tableswitch' and 'lookupswitch' instructions
The padding computed for 'tableswitch' and 'lookupswitch' instructions is incorrect.
It leads to invalid values for instruction size as returned by 'Instruction.size_of', and
'Instruction.compile'.

It also generates invalid destination offsets for such instructions when compiled by
the assembler. In this later case, a temporary workaround is to use 'nop' instructions
to "artificially pad" the instruction.

However, there is no problem when these instructions are used from either
'Instruction.encode' or 'Instruction.decode'.